Cylinder stations for high purity gases

Applications:

Cylinder stations are gas supply systems and serve as central gas supply in production plants and laboratories.

Cylinder stations are used for compressed gases as well as for gases dissolved under pressure to reduce the respective cylinder pressure and to keep the set back pressure constant.

For applications with high purity gases, our cylinder stations are equipped with a flushing gas valve as standard. Especially for applications with corrosive gases, our cylinder stations are equipped with a foreign gas flushing device.

Areas of application:

Cylinder stations for high purity gases up to a gas purity of 6. 0 are used, among other things, for applications in production plants or in the medical or chemical industry. Especially in laboratories they are used for the supply of ultra-pure gases.

Applications of the Cylinder stations are among others:

Cylinder stations are part of the central gas supply, where ultra-pure gas is extracted from individual cylinders or bundles of cylinders.

Products:

Our cylinder stations are available in different versions. In addition to the different pressure stages, there are cylinder stations in brass or stainless steel in

1-stage and 2-stage design for constant output pressure. For uninterruptible gas supply, 2-sided cylinder stations with manual or automatic switching are offered.

For oxygen use our gas supply stations are BAM approved for cylinder pressures up to 300bar.

HP230 gas supply station / single stage

The single stage gas supply station HP230 is designed to reduce an inlet pressure of max. 300 bar to an outlet pressure of max. 17 bar and to keep constant.

The HP230 is available in brass for non-corrosive gases and stainless steel for corrosive gases.

More

HP231 gas supply station / dual stage

The dual stage gas supply station HP231 is designed to reduce an inlet pressure of max. 300 bar to an outlet pressure of max. 12 bar.

Due to the 2-stage design, the outlet pressure is kept constant even with decreasing inlet pressure. The HP231 is available in brass for non-corrosive gases and stainless steel for corrosive gases.

More

HP236 gas supply station / single stage / external purge system

The single stage gas supply station HP236 is designed to reduce an inlet pressure of max. 300 bar to an outlet pressure of max. 17 bar and to keep constant.

The HP236 is available in stainless steel for corrosive gases.

More

HP237 gas supply station / dual stage / external purge system

The dual stage gas supply station HP237 is designed to reduce an inlet pressure of max. 300 bar to an outlet pressure of max. 12 bar.

Due to the 2-stage design, the outlet pressure is kept constant even with decreasing inlet pressure. The HP237 is available in stainless steel for corrosive gases.

More

HP240 gas supply station / single stage / manual changeover

The single stage gas supply station HP240 with manual changeover is designed to reduce an inlet pressure of max. 300 bar to an outlet pressure of max. 17 bar and to keep constant.

The HP240 is available in brass for non-corrosive gases and stainless steel for corrosive gases.

More

HP241 gas supply station / dual stage / manual changeover

The dual stage gas supply station HP241 with manual changeover is designed to reduce an inlet pressure of max. 300 bar to an outlet pressure of max. 12 bar.

Due to the 2-stage design, the outlet pressure is kept constant even with Due to the 2-stage design, the outlet pressure is kept constant even with decreasing inlet pressure.

The HP241 is available in brass for non-corrosive gases and stainless steel for corrosive gases.

More

HP250 gas supply station / single stage / automatic changeover

The single stage gas supply station HP250 with automatic changeover is designed to reduce an inlet pressure of max. 300 bar to an outlet pressure of max. 12 bar and to keep constant.

The HP240 is available in brass for non-corrosive gases and stainless steel for corrosive gases.

More

HP251 gas supply station / dual stage / automatic changeover

The dual stage gas supply station HP251 with automatic changeover is designed to reduce an inlet pressure of max. 300 bar to an outlet pressure of max. 12 bar.

Due to the 2-stage design, the outlet pressure is kept constant even with Due to the 2-stage design, the outlet pressure is kept constant even with decreasing inlet pressure.

The HP251 is available in brass for non-corrosive gases and stainless steel for corrosive gases.

More
Further types of our “ cylinder stations for high purity gases” can be found in our catalogue

Your advantages

Our cylinder stations in particular have proven themselves through reliability, high functionality and durability. Well-known gas companies have been using our products for years. Consistency and quality are the hallmarks of our pressure regulators and the satisfaction of our customers confirms our actions.

Benefit from our flexibility, short delivery times and product variety. Together we will find an individual solution for your technical application.